<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15688</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: plate length wrong.  Remove plate from load table and configure bay
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check for messages in diagnostics regarding the plate.  These messages
begin with "Warning:" and should indicate the problem that is causing
this error. The measured plate size and its error are also reported.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Manually remove plate and confirm through workstation.  Ensure that
the plate dimensions match those configured for the workstation.
</text></DescriptionText>
</OperatorAction>
<Cause>
During loading of the plate onto the load table, the mainscan size of
the plate is measured. If the plate is not within
nvs.cfg.load.plate_length_tol, this error is generated.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:20 2008 PST
</Updated>
<Links>
</Links>
</Error>